Version
|
Release Date
|
Additions & Changes
|
Wavewin G.Q |
08 / 04 / 2014 |
-
Data Plotting (Scale by Units): Added a new Auto Scale mode to Scale channels according to the
channel units. Current channels are scaled with respect to each other and Voltage channels
are scaled with respect to each other.
-
Data Plotting (Super Impose): Added support to have multiple super imposes in the analog channel
plot screen. To superimpose a group of analog channels first mark the channels the press F7. To
turn superimpose off for a group of channels unmark the channels and press F7.
-
Data Plotting (Plot Single Ended FL): Added support to plot the Single Ended Fault Location in the
Data Plotting window. A new button was added to the Single Ended Radial and Reactance tabs to
plot the FL for the whole record or between bars.
-
Data Plotting (Plot Double Ended FL): Added support to plot the Double Ended Fault Location in the
Data Plotting window. A new button was added to the Double Ended dialog to plot the FL for the whole
record or between bars.
|
Wavewin G.P |
07 / 20 / 2014 |
|
Wavewin G.M |
04 / 10 / 2014 |
|
Wavewin G.3 |
03 / 25 / 2013 |
|
Wavewin F.Z |
02 / 07 / 2013 |
|
Wavewin F.Y |
01 / 14 / 2013 |
-
File Manager (Passed File Parameter): When a file is passed as a passed parameter to Wavewin it use to
first open the file manager then open the passed file. It now just directly opens the file. Directories
that have thousands of file takes allot of time to load. This version speeds up the display of
passed files.
-
Data Plotting (Drag and Drop Analog Channels): Added the ability to drag and drop mark analog channels
to a new position in the analog trace section.
|
Wavewin F.X |
12 / 17 / 2012 |
|
Wavewin F.W |
11 / 28 / 2012 |
|
Wavewin F.T |
10 / 10 / 2012 |
-
File Manager (Networked Drives): Improved the reading of the drive letter from the network drive
name. In previous versions the network drive was read from the information between the last ( )
symbols in the string. In some cases the information between last ( ) symbols is not the network
drive. It now looks for the ':' between the ( ). If not found then go to the next () symbols.
-
Data Plotting (Mark & Save): Corrected a problem with the mark and save not reading the selected
format file correctly from the menu option.
|
Wavewin F.Q |
08 / 20 / 2012 |
-
File Manager (User Shortcuts): Added user defined shortcuts to menu options in the File Manager
and Data Plotting windows. To define shortcuts open the the File Manager's Display dialog (located
under the Options menu). Click the Shortcuts button. Two tabs are displayed below the dialog
definition "File Table" and "Data Plotting". To add shortcuts click the menu options under the
"Actions" list and click the Move button (green arrow). Shortcuts can be deleted, moved up and
moved down in the list. A drop down menu button is displayed in the button menu bar with the
selected shortcuts.
|
Wavewin F.P |
08 / 03 / 2012 |
-
Data Plotting (Fast SACs): Added support to add new SAC header and operators to the Fast SAC
file by the users. The Fast SAC file (SacList.FMT) is not included with the downloaded zip file.
When the system is ran Wavewin will look for the SacList.FMT file if it is found it will read
and bin the contents into memory. If it is not found it will create it with the 16 default SAC header
and operators.
-
Data Plotting (Save As Comtrade): Added support to clean all illegal filename characters,
carriage return and line feeds from the station and device names before saving to Comtrade
using the IEEE long file naming format.
-
Windows 7 (Dialogs): Adjusted the dialog sizes to accommodate the screen size. If a dialog is larger
than the screen then scroll bars are displayed to scroll through the dialog. Also, automatically
size the dialog according to the dialog fields and not as default values.
-
Windows 7 (ASCII Editor): Adjusted the ASCII text marking to mark the text with reference to the font
character width and not the default width. Some Windows 7 systems have character sizes that are
different from the defined default width.
-
Windows 7 (Date and Time Blinking): Minimized the date and time blinking in the systems main menu
bar by turing off the Transparent field.
|
Wavewin F.N |
06 / 24 / 2012 |
|
Wavewin F.F |
06 / 04 / 2012 |
|
Wavewin F.D |
07 / 05 / 2011 |
-
File Manager (Default Path): Added support to define the default path the file manager will
always open in. To define the file manager's default path, select the "Display" menu option
under the "Options" menu. Enter or browse to select the desired path in the "Default Path" field.
When the file manager is opened it will attempt to display the folders and files in the default path,
if it cannot connect to the default path then the Wavewin path is displayed.
-
Data Plotting (Sequence Calculator): Added the display of the phasor chart to the sequence calculator.
Also, added support to display the sequence calculator for a single end or if two files are open
display the sequence calculator for both end to end files. Also, added the selection drop down lists
to define the channels for VA, VB, VC, IA, IB and IC.
-
Data Plotting (Fault Calculator: Double Ended): Simplified the Double End Fault Calculator. The new
Double Ended Calculator displays the input fields: Z1 (Mag and Angle) and the Line Length on the left
side of the window and the Fault location Output fields (Zero Sequence - FL0, Positive Sequence -
FL1, Negative Sequence - FL2) in the middle of the window. To display more details such as the data
values, the channels for VA, VB, VC, IA, IB and IC and the sequence components magnitude and angles
click on the "Show Details" button.
|
Wavewin F.C |
06 / 12 / 2011 |
-
Data Plotting (Merge Open Files): Corrected a scale factor conversion when merging open files that have
been converted from the original values to primary or secondary quantities.
-
Data Plotting (Save As): Corrected a typo in the Save As menu under the CSV menu.
|
Wavewin F.A |
04 / 10 / 2011 |
-
Data Plotting (Digital Channel Original State): Added the default view to view all digital channels
when there are no original state values defined in the Comtrade CFG file. Also, set the digital
channel state at the cursor position to a red "D" in the digital channel table to define that
the channels original states where defaulted to 0.
-
Data Plotting (Analog Channel Zero Axis Dotted Line): Corrected a problem when plotting the zero
x-axis dotted line. The previous version was plotting the zero x-axis as a solid line when in a
compressed view.
-
Data Plotting (Under and Over Triggers in SACs): Modified the way the under and over trigger
checking is performed in the SACs.
|
Wavewin E.Y |
12 / 07 / 2010 |
|
Wavewin E.V |
08 / 23 / 2010 |
-
System (Passed Parameter): Added a new passed parameter to automatically convert a file to the
IEEE C37.111 Comtrade ASCII 1999 format. The new passed parameter is /Comtrade. To retain the
original file name of the source file use the /Comtrade passed parameter. To have the file
automatically named using the IEEE C37.232 file naming format use the /Comtrade=1 passed
parameter. The /Comtrade command line parameter can also be used in batch files. The converted
Comtrade files are saved in the same directory as the source file. The new passed parameter will
convert the source file to Comtrade then display the converted Comtrade file in the data plotting window.
Below are some examples:
Examples:
---------
1.) Passed Parameter: "c:\faultlib\shipdir\SEL-421.CEV" /Comtrade=1
Comtrade Filename: 011207,145119291000,-5,Station A,Relay 1,SOFTSTUF,TRIP,,SOTF B_PHASE C_PHASE GROUND 50,60.00.DAT
2.) Passed Parameter: "c:\faultlib\shipdir\DATA1068.RCD" /Comtrade
Comtrade Filename: c:\faultlib\shipdir\DATA1068.DAT
|
Wavewin E.U |
08 / 17 / 2010 |
-
Data Plotting (Save Sample Values): Added a new menu option to the "Save As CVS" option. The new
option will Save the Vector values in RMS and Angle. The four Save As options are now:
1.) Save As CSV - RMS Values: Save the RMS Values in a comma delimited format.
2.) Save As CSV - Instantaneous Values: Save the Instantaneous Values in a comma delimited format.
3.) Save As CSV - Vector Values (Mag & Ang): Save the DFT Magnitude and Angle in a comma delimited format.
4.) Save As CSV - Vector Values (RMS & Ang): Save the RMS Value and Angle in a comma delimited format.
-
Data Plotting (Harmonics): Increased the number of harmonics displayed from Samples/Cycle div 2 to the
number of Samples/Cycle. Allows to see the mirror image of nyquist harmonics.
|
Wavewin E.T |
08 / 05 / 2010 |
-
Data Plotting (Save Sample Values): Added a new menu option "Save As" to the "File" menu. There are
two sub-menus under the "Save As" option: "Comtrade" and "CSV Format". The "Comtrade" option saves
the displayed channels in either the ASCII or Binary format. The "CSV Format" will save the RMS,
Instantaneous or Vector (Magnitude and Angle) values to comma delimited text file. The first
line in the CSV file is the header information for each channel. All the analog channels that
can be displayed in the active data plotting are saved. A dialog box is displayed to enter the
destination path and the filename. The destination path is automatically defaulted to the active
path in the file manager. The filename can be directly entered into the "File Name" field or the
file can be automatically named using the IEEE long file naming format. To have the file
automatically named click on the "ComNames" check box. If the "ComNames" check box is checked then
the File Name field will be disabled. To enter a file name make sure the "ComNames" check box is unchecked.
|
Wavewin E.R |
06 / 27 / 2010 |
-
Data Plotting (Sequence Calculator): Added a Sequence Components calculator. The sequence calculator
works off the active (highlighted) data plotting record. The channels in the active record must
be organized as follows: The first 3 visible channels are the Voltage channels, VA, VB and VC.
The next 3 visible channels are the Current channels, IA, IB and IC. To reposition the analog
channels first mark the channels then use the plus key to move the channels up one position and
the minus key to move the channels down one position. The values populated in the dialog are
read at the data bar position in the active record. The sequence calculator dialog is a stay
on top window. This allows for repositioning the data bars without closing the dialog.
To refresh the Voltage and Current values in the dialog use the Refresh button. Use the Calculate
button to calculate the sequence components.
To increment the voltage and current angles enter an increment value in the Angle Rotation fields
and click on the Rotate button.
To open the sequence calculator dialog select the "Sequence Calculator" menu option under the "Data" menu.
Data Plotting (Primary/Secondary Ratios): Added the abilty to change the primary and secondary ratio
values for the analog channels in the open record. To change the ratio values open the "Window's
Properties" dialog by selecting the "Window's Properties" menu option under the "File" menu.
Click on the "Driver Data Type" tab then click on the "Edit Ratio Values" button under the
"Analog Values" section. In the Ratio Values dialog move the cursor to the specific Primary/Secondary
values and change the displayed value. To apply the modified ratios click on the "OK" button.
The modified ratio values are Not saved to the original file on disk. To save the ratios values
to disk use the "Save As Comtrade" option listed under the "File" menu.
Data Plotting (Peak/RMS Type): All analog channels displayed are viewed as Peak type. To change the
type of values displayed, open the "Window's Properties" dialog by selecting the "Window's
Properties" menu option under the "File" menu. Click on the "Driver Data Type" tab then select
the Data Multiplier type from the drop down list under the Analog Data Type section. To always
have the driver specific files displayed as RMS type (Root 2 Multiplier) open the "Driver
Configuration" dialog from the File Manager's "Option" menu. The Driver Configuration dialog
lists all display drivers supported, click on the driver in the "Drivers" list then change
the Driver's Data Type to RMS calibrated.
Data Plotting (Data Cursors): Corrected a problem with displaying the data bar in non-active data windows.
|
Wavewin E.L |
04 / 26 / 2010 |
|
Wavewin E.J |
04 / 21 / 2010 |
|
Wavewin E.H |
04 / 14 / 2010 |
-
Data Plotting (Print Profile): Added the ability to save a print profile file when saving a view file.
The print profile fields where added to the "Save View" dialog. The "Save View" dialog is a menu
option under the "View" menu. The "Save View" dialog now has the ability to manipulate the channels
in the view and to specify the print orientation and the type of ASCII Summary information to print
Short=General Information, Advanced=General Information plus Channel Information.
|
Wavewin E.F |
01 / 14 / 2010 |
|
Wavewin E.E |
12 / 22 / 2009 |
|
Wavewin E.D |
12 / 10 / 2009 |
|
Wavewin E.C |
11 / 30 / 2009 |
|
Wavewin E.7 |
10 / 12 / 2009 |
-
Data Plotting (SACs): Added 2 new SAC operators: "s" (Sin) & "c" (Cos). The "s" operator is
used to compute the sin "c" is cos. These two new operators allow for calculating Power
factor, Actve and Reactive Power. Refer to the SAC help window for application examples.
-
Data Plotting (Harmonics): Added a white background behind the harmonic values in the histogram
display. This make the numbers more readable.
|
Wavewin E.6 |
09 / 28 / 2009 |
-
Data Plotting (Change Frequency): Added support for Changing the Frequency for Comtrade files that
have a zero defined as the Sampling Rate. The change frequency engine calculates the fractional
difference between the old frequency and new frequency once before performing the change frequency
for each sample. Added the fractional difference for each sample.
-
Data Plotting (Primary/Secondary): Added resizing to the analog table column's width when changing
the type of data displayed, primary and secondary.
-
Data Plotting (Save As Comtrade): Corrected a problem Saving a File As Comtrade from the data window
when the File Manager table is closed. The Save As Comtrade engine was trying to access the File
Manager's translate strings.
-
Data Plotting (Phase Angles): Added an option to toggle between showing the Cos Convention
(0 Deg at Positive Peak) and the Sin Convention (0 Deg at Zero Crossing) for the phase angles. The
new option is in the Window Properties dialog under the Display Settings tab.
|
Wavewin D.Z |
06 / 12 / 2009 |
-
Data Plotting (Syncrophasor Support): Modified the phasor displays to follow the syncrophasor
convention (+Peak=0 Degrees).
-
Data Plotting (SACS): Added a set of fast recursive engines for calculating RMS, Phase,
Magnitude, Real, Imaginary and frequency components for each channel.
-
Data Plotting (SACS): Added 8 new SAC operators using the values calculated from the recursive
engines. The new SACS operators are:
"x": real component
"y": imaginary component
"m": magnitude
"d": angle
"r": true rms
"f": cyclic frequency
"q": instantaneous frequency
"t": delta time frequency
-
Data Plotting (SACS): Added a number of examples in the SAC help window describing how to
use the new and existing operators.
-
Data Plotting (Time Discontinuity): Added a new engine to detect discontinuities in time. If
a time discontinuity is encountered then a green dotted line is displayed at the sample where
the discontinuity occured. A mouse over the small gray triangle displayed at the bottom of the
green line will show the duration. To turn off this feature set the "Show Event Separator Bars"
field to "No" (in the properties dialog).
-
Data Plotting (Harmonics): Changed the displayed Total Harmonic Distortion value from RMS to
Instantaneous (for compliance with IEEE notation).
-
Data Plotting (Summary): Revised the Summary Window to show: Max, Min & Max Min Difference for
both Instantaneous and RMS values.
-
Data Plotting (Navigate Peaks): Revised navigate peaks to navigate the DFT peaks instead of the
instantaneous peaks.
-
Data Plotting (Print): Added the time line and ruler to the print engines.
-
Data Plotting (Append): Corrected a problem appending log files. The time difference between
the selected append files was being calculated to the microsecond. It is now calculating the
difference according to seconds.
|
Wavewin D.N |
06 / 24 / 2008 |
|
Wavewin D.M |
06 / 12 / 2008 |
-
Data Plotting (Print Window): Added a new print option to print the contents of the window. The
new option is called "Window" and is located under the "Print" submenu.
-
Data Plotting (Print All & Page): Corrected a problem printing the analog table. The
columns where being resized improperly.
|
Wavewin D.K |
05 / 29 / 2008 |
-
Data Plotting (Summary): Compressed the Fault Summary information into 4 lines for the SEL compressed
format. Previous versions were using 12 lines for each event saved in the file. There is a limitation
of 40 lines for the fault information section. Up to 10 event's fault information is now displayed.
-
Data Plotting (Print): Included the Waveform Summary as part of the data plotting print.
-
Data Plotting (Analog Table): Added automatic column sizing according to the largest max & min
values. Previous versions were using a fixed size which was causing values to overlap into neighboring
columns.
|
Wavewin D.G |
02 / 25 / 2008 |
-
File Manager (Network Drives): Corrected an error when navigating network drives. In previous
versions if there are 2 sets of () in the network name Wavewin was extracting the drive letter
from the first set of (). This is not the case, Windows puts the drive letter in the last set of ().
In this version Wavewin extracts the drive letter from the last set of (). This corrects any
access violation errors encountered when navigating to network drives.
-
File Manager (Network Drives): Greatly improved the speed when reading the directories under a
network drive. Wavewin is now a 100% compatible with Windows explorer when navigating to network drives.
|
Wavewin D.D |
01 / 21 / 2008 |
-
Data Plotting (User Views): Improved the user views by including the following information in the view:
sampling frequency, time scale, sliding window size, phasor window size, table window size,
red fault bar, auto scale and phasor or circular chart displayed.
|
Wavewin D.C |
01 / 03 / 2008 |
|
Wavewin D.B |
12 / 13 / 2007 |
|
Wavewin D.A |
12 / 03 / 2007 |
|
Wavewin D.9 |
11 / 05 / 2007 |
-
Data Plotting (Save Views): Added a new option to save analog and digital channel views to an
ASCII text file. To save a view mark the desired analog and digital channels and press enter.
Select the "Save View" menu option under the "View" menu. Enter the views filename and path and
press enter. The saved view will be added to the views drop down list on the menu button bar. The
views drop down menu list displays the last 15 saved or selected views.
-
Data Plotting (Select Views): Added a new option to select saved views. To display a saved view
select the view file from the "Views" drop down list displayed in the menu button bar. If the
desired view is not displayed in the drop down menu list select more views to navigate to the
saved view. Views can also be selected using the "Select Views" menu option under the "View" menu.
The "Select Views" dialog list all the view files in the active view path. To change the view path
select a path from the "View Path:" drop down list or use the browse button to select a new path.
The analog and digital table displays the properties of the selected view.
|
Wavewin D.4 |
09 / 09 / 2007 |
-
Data Plotting: Fixed a problem with the Primary and Secondary values not being added to the Comtrade
files created during a command line merge operation. The primary and secondary values are now added
to the Comtrade .CFG files.
-
File Manager: Fixed a problem in the file tree when directory names are 1 character only. Previous
version were causing a access violation error when a directory was 1 character in length.
-
Data Plotting: Corrected a problem when using the command line to merge trend files.
-
Data Plotting: Fixed a problem with updating the file's date and time in the window's header
when the automatic Adjust Files Time is implemented. The files time was adjusted after the window's
header was updated.
-
Data Plotting: Upgraded all of the time calculations from the old 32 bit, integer infrastructure to a
new 64 bit, floating point structure. This upgrade has eliminated the errors that were caused by
accumulated truncations.
|
Wavewin C.V |
03 / 29 / 2007 |
|
Wavewin C.T |
03 / 23 / 2007 |
|
Wavewin C.S |
03 / 12 / 2007 |
|
Wavewin C.R |
02 / 27 / 2007 |
-
System: Did more work on resizing more of the dialogs and windows to handle the Microsoft Monitor 120 DPI setting.
-
System: Added the advanced captions, hint and strings to the translation files.
|
Wavewin C.Q |
02 / 05 / 2007 |
-
Fault Location: Rearranged the fault location dialog according to Pete Vivers email dated 01/24/2007.
Added an Advanced button to allow users to change the Phase Selection mode and for editing the Z1
and Z2 % of line, R0 and Rg division factors and the threshold fields.
-
Fault location: Added the automatic display of the change frequency dialog box when the file's current
sampling frequency is not set to 24 samples/cycle.
-
Data Plotting: Fixed an error in the change frequency engine when changing from a high frequency to a
low frequency. The previous algorithm was not taken the fraction portion of the difference between the
old and new frequencies. This has been corrected and is now working.
-
Data Plotting: Added support to handle the comma as a decimal separator in the fault location dialog
and in the change frequency dialog.
-
System: Added resizing to a number of dialogs and windows to handle the Microsoft Monitor 120 DPI setting.
|
Wavewin C.P |
01 / 22 / 2007 |
|
Wavewin C.O |
01 / 07 / 2007 |
-
Data Plotting: Fixed a problem with calculating the total number of samples sent to the
SingleEndFaultLocation.dll. The previous version was using the fault trigger position defined in the
Comtrade CFG file to calculate the total number of samples to send to the DLL. This problem has been
corrected, it now uses the reference bar position to calculate the total samples.
-
Data Plotting: Included all Fault location message strings to the SIL & SIB files.
-
Data Plotting: Added a call to Get Last Error for all function calls in the fault location dialog.
Also increased the length of the output fields to fit the Fault time information.
-
Data Plotting: Changed the fault reference position to the Reference bar (blue dotted line).
This allows the user to change the fault position by right clicking in the trace window.
-
Data Plotting: Added a print button to screen dump the contents of the fault location dialog.
|
Wavewin C.N |
12 / 20 / 2006 |
-
Data Plotting: Added a Fault Location dialog to interface to Areva's fault location DLL (SingleEndFaultLocation.dll).
To open the new dialog select the Fault Location menu option under the Data menu. Before opening change the sampling
frequency to insure 24 samples per cycle. Enter all of the Input fields in secondary quantities. An error message
will be displayed if there is a problem with the input settings. Select the proper channels in the Analog Channel
section then press the Start button. The results will be displayed in Output section. Any errors or warnings will
be displayed in the Errors & Warning text box. The fault location dialog sends all samples values in secondary
quantities. The number of samples sent depends on the values defined in the pre and post reference bar fields in
the Analog Channels section. The start sample and the number of samples sent is displayed in the status bar.
-
Data Plotting: Added support to read Comtrade ASCII *.DAT files that include blanks between the data values
and the comma separator. The complier method used for converting the string to interger values was returning
an error because of the included blanks. Added support to delete all blanks before converting the string to
an integer.
-
Data Plotting (Properties Dialog): Added a new button in the "Windows Properties" dialog under the "Driver Data Type"
tab. The "Analog Values" section allows for viewing each channels Primary & Secondary ratio values. Click on the
"View Ratio Values" button to display all of the analog channels Primary & Seconday values.
|
Wavewin C.J |
08 / 04 / 2006 |
-
Data Plotting: Added a new selection option to switch between Primary and Secondary values. To change
the analog values open the Windows Properties dialog by clicking on the "P" menu button, or select
the "Window Properties" menu option from the "File" menu. Click on the "Driver Data Type" tab and
select Primary or Secondary from the "Analog Values" section then click OK. The type of analog values
displayed is defined in the Data Plotting's Window header after the Fault Date & Time.
-
Data Plotting (Printing): Fixed a problem with the print engine. When an ASCII Comtrade text file uses
a Line feed (OA) only for the line seperator the Comtrade ASCII read engine was not reading the last
sample in the file. The number of samples plotted did not equal the total number of samples defined in
the Comtrade CFG file. This was causing the print engine to issue an endless number of blank pages
because it was never getting to the total number of samples defined in the CFG file.
|
Wavewin C.I |
07 / 10 / 2006 |
-
System: Added support to process Batch files through the passed parameters. The Batch passed paramter must be passed for the batch
processing to successfully be implemented. The Batch file can contain files to print and files to view. Wavewin can display a
maximum of 10 data plotting windows and a maximum of 10 ASCII text files at one time. When using the Batch command for viewing
files have no more than 10 data plotting files and 10 ASCII text files specified in the batch file.
-
Data Plotting (SACs): Added more protection to avoid Access Violation Errors when improper information is
entered in the operator fields.
-
File Manager: Fixed a problem when trying to access directories using networked computer names: \\other machine\fault files.
|
Wavewin C.H |
06 / 15 / 2006 |
-
Data Plotting: Fixed a problem with the F9 function key for files with digital channels only.
-
Data Plotting (SAC Window): Added 4 new buttons in the SAC window to save / open SAC files. The
new "Save" and "Save As" buttons allow for saving the current SAC information into an ASCII text file. The new
"Open" button allows for reloading previously saved SAC files. The "New" button allows for creating new SAC files.
|
Wavewin C.G |
05 / 16 / 2006 |
-
System: Fixed a problem with the /print passed parameter. In previous versions it was required that
the contents of the window be fully painted on screen before the print occurred. When too many prints
were issued close together a range check error was generated because the screen information was not
fully painted. We modified the print to work with a virtual graphics handle instead of using the window's
graphics handle.
-
File Manager: Corrected a problem with the unzip components used to unzip the .ZAT files. Frederic reported
that a message box was displayed from the ZipTV components stating that the components were not
registered. We corresponded with ZipTV and have corrected the problem. The components on
Softstuf's development stations were not properly registered.
-
Data Plotting: Harmonics, added a check to avoid the bar width going under 1.
|
Wavewin C.F |
04 / 14 / 2006 |
-
System: Fixed a number of problems and made some changes to the passed parameters:
Changed the /X1 and /Y1 passed parameters to /X and /Y. There was no need for the 1 indicator since we changed /X2 and
/Y2 to /W and /H
Fixed a problem with the /Print passed parameters on slower machines. The print function was being called before the
the paint method for the window.
Corrected a problem with viewing files.
Corrected a problem with the /TopMost passed parameter.
-
Data Plotting: Added an option in the Harmonics window to change the bar size to show as many harmonics as possible
in one screen.
-
Data Plotting: Changed the units for the time bar and Delta X status bar to show time in a readable format. We also added
a unit and color indicator according to the time displayed.
|
Wavewin C.E |
03 / 23 / 2006 |
-
System: Added more resizing for the dialogs to support the Spanish and German languages.
-
System: Added Frederics suggestions for passed parameters and also fixed a few problems with the new passed parameters.
-
Data Plotting: Added a fixed dotted light red fault bar, also added an option in the properties dialog to show
or hide the fault bar.
-
Data Plotting: Added resizing to the harmonics window to view as much information as needed.
|
Wavewin C.D |
02 / 21 / 2006 |
-
System: Added support to view
Wavewin Areva in different languages. First language added was French. All remaining languages can be added
to the SIL and SIB files without further coding in the software. Also all menu items have been added
to the SIL and SIB files. To change the active language in the Wavewin Areva software select the "Display" option
under the "Options" menu in the File Manager. Select the desired language from the "Languages" drop down list.
-
File Manager: Moved the last active directory to the Wavewin.ini File. In previous versions the last active
directory was saved to the Template database that has a limit of 80 characters. The Wavewin.ini eliminates
the 80 character limit.
-
Data Display: For files that have digital channels only made sure that all digital channels are displayed if there
are no triggered channels in the file.
|
Wavewin C.A |
11 / 28 / 2005 |
-
File Manager: Added sorting to the table folder tree.
-
File Manager: Always open Wavewin's folder tree to the last active directory.
-
Data Plotting: Fixed a problem with the boundary check for Comtrade ASCII digital channels.
-
Data Plotting: Fixed a problem with calculating the sampling frequency for Comtrade files that define
a zero for the sampling frequency.
-
Data Plotting: Increased the maximum number of harmonics displayed in the harmonics table from 100 to 200.
|
Wavewin C.7 |
09 / 12 / 2005 |
|
Wavewin C.6 |
08 / 15 / 2005 |
-
Data Plotting: Improved the Harmonics window to display as many harmonics as possible based on
the sampling frequency.
-
Data Plotting: Fixed a problem with the Comtrade read engine. The last analog channel's data was not
being read. The last channel's values were defaulted to zero. The Comtrade engine was recently modified so that
a maximum of 255 analog channels is displayed if there are more than 255 channels defined in the file.
The maximum analog channel boundary was not being checked properly therefore the last analog channel
was not being read.
|
Wavewin C.5
|
08 / 08 / 2005
|
-
Data Plotting: Added two new columns to the Analog
table. DFTMag = Displays the DFT Magnitude calculated between the RMS
bar
(black dotted line) and the data bar (solid data bar). Crest =
Displays the DFTMag column divided by the
RMS column.
-
Data Plotting: Added a new field in the harmonics dialog called "Total Harmonic Distortion" (THD). The
"Total Harmonic Distortion" field displays the ((sqaure root of the summation of the squares
of DFT Magnitudes from harmonic 2 to the maximum harmonic) divided by square root of 2) and that
quantity divided by the DFT Magnitude of the Fundamental.
-
File Manager: Fixed a problem with the status bar fields not updating when navigating via the tree.
-
File Manager: Modified the table sort engine to always sort the columns in upper case. The previous sort engine
was sorting the column data as is. This was causing a problem when files are named with upper case and lower case.
-
Data Plotting: Fixed a problem with reading multiple binary Comtrade files. The Comtrade binary read multiple files
was not reading the files in proper sequence.
-
Data Plotting (SACS): Fixed a problem with the SACS returning an error when calculating an Envelope using the
"A" and "E" script commands.
-
Data Plotting: A number of requests have been made to change the way the expand and condense time displays
the waveform signals. In versions previous to C.3 the expand and condense would display the first sample out of
the group of samples to condense or expand. To better show the peaks we changed that functionality in version C.3
to pick the hightest value in the group of samples to condense/expand. This still did not show all the information.
In this version Wavewin now displays all of the samples in the file. When the signals are condensed the samples
are plotted over each other.
-
Data Plotting: Added a feature to hop the data bar by one cycle for waveform files and one day for load files.
This feature is keyboard activated, use the Shift+Ctrl+Right/Left Arrows to move the data bar one cycle/day from
the previous position.
-
File Manager: Added Cut, Copy and Paste to easily move files from one directory to another. The new Cut, Copy
and Paste features work in the same fashion as Window's Explorer. Use the following menu items or short-cut keys
to activate the added file features: Cut:(Edit Menu: Cut Option, Ctrl+X, Shift+Del), Copy:(Edit Menu: Copy Option,
Ctrl+C, Ctrl+Ins), Paste:(Edit Menu: Paste Option, Ctrl+V, Shift+Ins).
-
File Manager: Added shortcuts in the file table right click pop-up menu for Cut, Copy and Paste files and for
the Zip, Email and Refresh features.
-
File Manager (Save As Comtrade): Fixed a problem with Save As Comtrade for the 1991 and 1999 formats. The 1991
format was defining 3 fields (substation,device ID,version #) for the first line in the CFG file. The proper
format is substation,version #. Wavewin now puts the substation - Device ID,version#. For the 1999 format the
last line in the CFG file is the time multiplier for the sample times in the .DAT file. Wavewin was only adding
the time multiplier field to the CFG if it was greater than 1. Now it always adds the time multiplier field.
-
File Manager: Fixed a problem with reading the line frequency from the Comtrade ".CFG" file. The line
frequency was always defaulting to 60.
-
File Manager: Fixed a problem with the list of child windows being displayed under the wrong menu item.
-
Data Display: Added a medium display to the Auto Scale (F6, Atl-D, A) toggle feature. Auto Scale toggles between
(Off, On and ++). ++ plots the signal using the number of maximum pixels allowed for the channel. The highest value
is plotted at the maximum position allowed and the smallest value is plotted at the lowest position allowed. This
feature was added to clearly show the profile of frequency, Vdc and load data channels.
-
Data Display: Added a new option in the properties dialog under the Comtrade tab called: "Show Date
in (US/European/Japan) Format. This new option allows for selecting a fixed date format for the Comtrade
files.
-
Data Display: Fixed a problem with the fault time line when calculating if the time is greater then a k.
-
File Manager: Added a Directory Tree for easy navigation.
-
File Manager (Delete Files): Changed the way the delete files engine works. It will now send files that reside
on the computer to the Recycle Bin all others are permanently deleted.
-
File Manager (Rename Files/Folders): To rename a folder in the tree click on the folder name twice
to display the edit box. To rename files select the rename option from the Files menu.
-
File Manager: Added the ability to email marked files directly from the file table.
Click on the email menu button to activate. All support files are automatically attached to the
email message.
-
File Manager: Added the ability to zip marked files directly from the file table. To activate, open
the "File" menu and select "Zip Marked Files" option. All support files are automatically added to the zip file
upon confirmation.
-
Data Plotting: Added the ability to email the active event file. All support files
are automatically attached to the email message. To activate, click on the Email menu button.
-
Data Display: Added "Analog Input" & "External Input" as a non used channel. Wavewin does not show analog
and digital channels that contain the following strings:
UNUSE
UNDEF
NOT D
NOT D
NOT U
NOT I
NOT A
UNDEF
{
N/A
ANALOG INPUT
ANALOG CHANNEL
EXTERNAL INPUT
EVENT CHANNEL
CHANNEL:
DIGITAL TRACE #
SPARE
-
Data Display: Fixed the data display in the Windows XP display mode. The last digital channel was being
overwritten by the window's border. Also fixed the sizing of the Wavewin main application window to size
around the desk top toolbars.
|
Wavewin B.R
|
09 / 25 / 2004
|
|
Wavewin B.Q
|
08 / 16 / 2004
|
-
Data Plotting: Upgraded the "Save As Comtrade" engine to handle the older 1991 version and the newer 1999
version.
-
Data Plotting: Added a new field in the "Properties" dialog to select the Comtrade version for the "Save As
Comtrade" engine. The new field is in the "Comtrade" tab and is called "Save Using Comtrade Version:". Select
1991 for the older version and 1999 for the newer version. The default version is the newer 1999 version.
|
Wavewin B.P
|
06 / 16 / 2004
|
-
File Manager: Added a new feature to open multiple waveform files from the file table. Mark the files
desired and select the "Open Marked Files" menu option under the Options/Waveform File(s) menu. The
files will be tiled horizontally and the file manage will be minimized.
-
File Manager: Append Waveform Files: The two features available under the Options/Waveform File(s)/Append
menu will append all the marked waveform files in time either by deleting the common times between files
(Discard Common Times) or appending all marked files back to back (Back to Back), sorted oldest to latest.
The files must be of the same type.
-
File Manager: Merge Waveform Files: The two
features avaliable under the Options/Waveform File(s)/Merge menu will
merge different types of files into one display.
-
By Time: Merge channel samples if
they have a common time segment. The reference time is from the file
with latest start date and time. The file with the least amount of
samples determined the length of the new merged file.
-
By Sample: Merge regardless of
time stamps. The reference time is from the first marked file. And the
file with the least amount of samples determines the length of the
file.
When files with different
sampling frequencies are merged a dialog will be displayed. The dialog
contains a list of all the sampling frequencies in the marked files.
Select the frequency for the merged file or enter a new frequency.
To identify the merged channels the station name
for each file is added to the beginning of the analog and digital
channel names. To turn off this feature open the Properties dialog in
the data-plotting window. Click on the Append/Merge tab and uncheck the
“Add the File’s Station Name to Beginning of the Analog/Digital
Channels” field.
-
Data Plotting: Added a new feature Append Open
Files. There are two options available under the Append Open Files Menu
(same feature as the file manager’s Append):
-
Data Plotting: Added a new feature Merge Open
Waveform Files. There are three options available under the Merge Open
Files Menu:
-
By Time: Merge channel samples if they have a common time segment. The reference time is from the file
with latest start date and time. The file with the least amount of samples determined the length of
the new merged file.
-
Manually: Use the data bars to highlight where the common sample time is in each window. Merge
manually will then line up the data bars and adjust the time stamps accordingly. This option
is used when the file times are not synchronized. The active window determines the time stamp
of the new merged file and the open window with smallest number of samples determines the length
of the new merged file.
-
By Sample: Merge regardless of time stamps and/or data bar positions. The reference time is from the
active window. And the file with the least amount of samples determines the length of the file.
When files with different sampling frequencies are
merged a dialog will be displayed. The dialog contains a list of all the
sampling frequencies in the opened files. Select the frequency for the
merged file or enter a new frequency. Merging
Open Files allows for flexibility of what channels are merged. Merge
Open Files will merge either the marked channels only or if there are no
marked channels then it will merge the visible channels.
To identify the merged
channels the station name for each file is added to the beginning of the
analog and digital channel names. To turn off this feature open the
Properties dialog in the data-plotting window. Click on the Append/Merge
tab and uncheck the “Add the File’s Station Name to Beginning of the
Analog/Digital Channels” field.
-
Data Plotting: Added a menu button to gain easy access to the driver’s data type setting.
The data type setting specifies if the samples for the active driver are saved in RMS values
or in instantaneous values.
-
Data Plotting: Modified setting the sample time stamps in the Comtrade reader. If the sampling
frequency is set in the .CFG file then the time stamp is calculated from the sampling frequency.
If the sampling frequency is 0 then the time stamp is set from the time stamp in the .DAT file.
|
Wavewin B.L
|
04 / 01 / 2004
|
-
Data Plotting: Added support to read Comtrade files that are distributed into multiple data files.
-
Data Plotting: Fixed a problem with displaying SAC values when operating with RMS calibrated data.
-
File Manager: Added a new feature to Append like waveform files in time. A new sub menu
has been added to the "Options" menu called "Waveform File(s)". Use the "Open Selected Waveform
File" option to display the traces in the selected file. Use the "Append Marked Waveform Files"
option to append like waveform files in time. The marked file's analog and digital channels must match.
-
File Manager: Added a new feature to set up certain parameters for the append feature. Select the
"Waveform Properties" option under the "Waveform File(s)" menu option. To throw out samples with common times
check the "Discard Common Times" option. Next, select what file will have the times discarded from:
the new file being created or the files being appended.
-
Data Plotting: Added a new setting to set the Opening frequency for each supported driver.
To setup this parameter open the desired waveform file, next select the "Change Frequency" option from
the "Data" menu and check the "Always Open" box. The frequency entered into the New Frequency" field
will be the frequency displayed for all the files for the active driver.
-
Data Plotting: Added a new feature to Show/Hide the event separator bars for multiple event files. The
new field is in the "Properties" dialog under the "Display Settings" tab.
|
Wavewin B.J
|
02 / 29 / 2004
|
-
Data Plotting: Fixed a problem with displaying leading zeros for the fault time in the Waveform
Summary window.
-
Data Plotting: Added a new feature to the data plotting's "Data" menu to Truncate cycles.
Truncate can be applied to remove cycles from the beginning of the data, the end of the data
and from the middle of the data.
-
Data Plotting: Added a new feature to the data plotting's "Data" menu to Duplicate the cycle
of data between the RMS bar and the data bar. A dialog box allows for specifing the number of
cycles to add.
|
Wavewin B.H
|
02 / 12 / 2004
|
-
Data Plotting:
Added two new features to the data plotting's "Data" menu to change and restore the
sampling frequency.
"Change sampling frequency": This feature allows for changing the sampling frequency of the
displayed record. If Sync mode is active then Change Sampling Frequency will change all open
windows to the entered frequency.
"Restore Original Data": This feature is active only after the sampling frequency is changed.
It allows for restoring the original raw data of the displayed record. If Sync mode is active
then Restore Original will restore all the open windows to their original raw data.
-
Data Plotting:
Added 3 new options to the "Values" menu.
Mark Raw Samples - Draws a small circle on all the original raw samples.
Mark Peak Values - Draws a small square on all the peak values.
Mark Change in Sign Values - Draw a small triangle at all values where a change in sign occurs.
-
Data Plotting:
Modified the Channel Information, Summary and Raw Data menu buttons to indicate an ASCII
display with the corresponding character signifying the type of data.
-
Data Plotting:
Added a new menu button to open new files or to open one of the last 14 files opened.
-
Data Plotting:
Data Plotting: The data plotting window's menu has been arranged to be more windows compliant.
A large number of requests from Wavewin users asked to improve the menu.
Below are the additions:
- Added a new "File" menu. The "File" menu handles all commands directly related to the waveform file.
- Added a new "Open" command under the "File" menu to open new waveform files.
- The "Data" menu handles all commands relating to the data such as: Expand & Contract Time, Increase
& Decrease amplitude, auto scale...
- Added a new "Channel" menu. The "Channel" menu handles all commands directly related to the
Analog and Digital channels.
-
Data Plotting:
The "Display" dialog used for setting up the properties of the window has been moved to the
new "File" menu and is now called "Properties".
-
Data Plotting:
The "Displayed Device's Data Type" field in the "Properties" dialog (formally the "Display" dialog)
has been moved from the "General" tab to the "Display Settings" tab.
-
Data Plotting: Fixed a problem reading the sampling frequency in the Comtrade driver.
The driver was defaulting the sampling frequency to 0 if it was >32768 or <-32768. Took
out the limit and open ended the sampling frequency value.
-
Data Plotting: Added a new feature to save RMS Calibrated data as Peak data for the Save As Comtarde
option. This feature is optional. Change the "Convert RMS Calibrated Data" field in
the "General" tab of the "Properties" dialog to "Yes" to activate.
-
File Manager: Improved the speed of the File Manager's read engine. Enhanced the way the memory is
allocated when reading the file allocation table.
-
Data Plotting: Fixed a problem with the "Software Analog Channel" menu disappearing when the data
window is maximized.
-
Data Plotting: Took out the gray background from the digital channels in the print outs.
|
Wavewin B.A
|
10 / 17 / 2003
|
-
Data Plotting: Allowed for Comtrade Files to be displayed if the digital channels have
no original states set.
-
Data Plotting (SACs): Added a new operator to the instruction set, absolute value.
The "|" symbol is used to define the abs() function.
-
Data Plotting: Added two new buttons in the phasor/circular chart window title:
"P" to display the phasors at the data bar and "C" to display the circular chart.
-
Data Plotting: Fixed a problem reading Comtrade CFG files that use a line feed only as
an end-of-line marker.
-
Data Plotting: Added support to display Comtrade files that have digital channels only.
-
Data Plotting: Modified the equation for the fault time bar to have more resolution.
|
Wavewin B.7
|
07 / 28 / 2003
|
-
Data Plotting (Save Displayed Values): Added a new extension "*.mac" for the Save Displayed Values Feature.
-
Data Plotting (Save Displayed Values): Allowed for the Display Save Values File and Format File Window to
be independent of the data plotting window. Does not close the Save Values File and Format File Window
when closing the data plotting window.
-
Data Plotting: Enhanced the Fault time bar locator to look for the closes match defined by the selected format.
Prior versions looked for an exact match.
-
Data Plotting: Enhanced the Sync Time feature to look for the closes match. Previous versions looked for
an exact match.
-
Data Plotting: Corrected the Sampling Frequency for Comtrade Files that specify a time scale multiplier.
-
Data Plotting: Enhanced the Sync Manual Mouse Click to displace the mouse according to time difference.
Previous versions displaced according to click position.
-
Data Plotting: Corrected the Fault Time displayed in the Waveform Summary Window.
-
Data Plotting: Added a Prompt to ask to overwrite existing Comtrade files for the Save As Comtrade feature.
-
Data Plotting: Corrected the Save As Comtrade feature to save only the digital channels that are visible.
Previous versions were saving the digital channels when the digital section was hidden using the drag mouse.
|
Wavewin B.6
|
07 / 08 / 2003
|
|
Wavewin B.5
|
06 / 29 / 2003
|
-
Data Plotting: Advanced the Save Display Values option. Added user defined Templates.
Refer to the Data Plotting help window "Save Displayed Values" section for more information.
-
Data Plotting: Added and new menu option "Values". Allows for saving Values displayed
in the Analog Table to a text file (Mark & Save) in the default format or in the format
defined in the selected Template file. Provides "Open", "New" and "Clear" features for
the active Values file and provides "New" and "Open" features for the Template Files.
Refer to the Data Plotting help window "Save Displayed Values" section for more information.
-
Data Plotting: Added the Horizontal Bars to the print engine.
-
Data Plotting: Fixed a time scale problem with Comtrade files that specify a time scale multiplier.
|
Wavewin B.4
|
05 / 27 / 2003
|
-
Data Plotting: New time based display. New field "Trace Display Type" added to the "Display"
dialog under the "General" tab. Allows for toggling between a sample base display and a time based display.
-
Data Plotting: New Fault reference time bar. Shows the time difference from the fault time.
The units are defined in the Delta X status field.
-
Data Plotting: New Close button for the Phasor/Circular Chart window.
-
Data Plotting: New Close button for the Analog Channel Information Table.
-
Data Plotting: Changed the Reference Bar position to be at the fault time defined in the Selected file.
|
Wavewin B.3
|
05 / 11 / 2003
|
|
Wavewin B.2
|
04 / 23 / 2003
|
-
Data Plotting: Allowed for the Constants in the SACs to be real values. Previous versions
worked with integer values only.
-
Data Plotting: Changed the way the digital bits are displayed: a value of
1 = thick green line, a values of 0 = thin black line. The A and
N status next to the digital titles stay the same. They are set by comparing to the
original state, A = diffenent then original state, N = same as original state.
-
Data Plotting: SAC window (F5): new division, multiplication, phase shift,
set prefix, set units and constant operators:
division = ":"
multiplication = "*"
constants = "^"
phase shift = "@
prefix = "p="
units = "u="
examples:
+1/+2@120/+3@240/:^3/p=k/u=volts/ to get (+)Seq
+1/+2@240/+3@120/:^3/p=k/u=volts/ to get (-)Seq
+1/+2/+3/:^3/p=k/u=volts/ to get (0)Seq
+1/:2/u=ohms/ to divide channel 1 by channel 2
|
Wavewin B.1
|
03 / 27 / 2003
|
-
Data Plotting: Fixed a
problem in A.Y and A.Z with freeing memory.
-
Data Plotting: New scaling procedures
for the analog channels display that scale according to real
values. The previous scaling procedures scaled according to raw
values.
|
Wavewin A.Y
|
03 / 11 / 2003
|
|
Wavewin A.X
|
03 / 03 / 2003
|
-
Data Plotting: Two new fields in the properties dialog
for the save displayed values feature: First field is "Save
To". This field specifies where to save the data: to
a file, the windows clipboard or both. The second field is
"Save Type". This field specifies how to maintian
the file; append or rewrite.
|
Wavewin A.W
|
03 / 02 / 2003
|
|